LG Electronics THERMA V R32
Select an integration method below to see supported data points and features.
Monitored data points
Parameters available in the MelPump dashboard and reports. The "Control" column shows if you can also change the value from the app.
| Parameter | Description | Monitor | Control |
|---|---|---|---|
| Booster Heater 2 Status | Shows if the second backup electric heater is active | check_circle | remove |
| Flow Temp Boiler | Water temperature leaving the backup boiler | check_circle | remove |
| Booster Heater 1 Status | Shows if the first backup electric heater is active | check_circle | remove |
| Force Hot Water | Forces immediate hot water heating regardless of schedule | check_circle | remove |
| COP | Efficiency ratio - heat output divided by electricity input | check_circle | remove |
| Compressor Frequency | Speed of the compressor in Hz, higher values mean more heating or cooling power | check_circle | remove |
| Defrost Mode | Indicates when the outdoor unit is melting ice buildup | check_circle | remove |
| Delta Temp | Difference between the water leaving and returning to the heat pump, used to show how much heat is being transferred | check_circle | remove |
| Operation Mode | Current mode: heating, cooling, or hot water production. May also show other modes like antifreeze or legionella. | check_circle | tune |
| Tank Water Temp | Current temperature of the domestic hot water stored in the tank | check_circle | remove |
| Target Tank Water Temp | Desired domestic hot water tank temperature | check_circle | tune |
| Input Power | Estimated electrical power being consumed | check_circle | remove |
| Output Power | Estimated heat energy being produced | check_circle | remove |
| Error Code | Diagnostic code shown when there is a problem | check_circle | remove |
| Has Error | Indicates if the system has an active error | check_circle | remove |
| Flow Rate | Amount of water flowing through the system in litres per minute | check_circle | remove |
| Flow Rate | Amount of water flowing through the system in litres per minute | check_circle | remove |
| Indoor Temp #1 | Current air temperature in rooms served by heating zone #1 | check_circle | remove |
| Thermostat Temp #1 | Desired room temperature set for heating zone #1 | check_circle | tune |
| Return Temp | Water temperature returning to the heat pump from the heating system | check_circle | remove |
| Operation Mode | Current mode: heating, cooling, or hot water production. May also show other modes like antifreeze or legionella. | check_circle | tune |
| Water Pump 3 Status | - | check_circle | remove |
| Operation Mode | Current mode: heating, cooling, or hot water production. May also show other modes like antifreeze or legionella. | check_circle | tune |
| Outdoor Temp | Current outside air temperature measured near the heat pump | check_circle | remove |
| Flow Temp | Water temperature leaving the heat pump and going into the heating system | check_circle | remove |
| Power | Whether the heat pump is turned on or off | check_circle | tune |
| Water Pump 2 Status | - | check_circle | remove |
| Water Pump 1 Status | Shows if the water circulation pump is running | check_circle | remove |
| Indoor Temp #2 | Current air temperature in rooms served by heating zone #2 | check_circle | remove |
| Thermostat Temp #2 | Desired room temperature set for heating zone #2 | check_circle | tune |
| Flow Temp #2 | Water temperature supplied to heating zone #2 | check_circle | remove |
| Prohibit Heating Hot Water | When enabled, prevents hot water heating | check_circle | remove |