Daikin Altherma
Select an integration method below to see supported data points and features.
Monitored data points
Parameters available in the MelPump dashboard and reports. The "Control" column shows if you can also change the value from the app.
| Parameter | Description | Monitor | Control |
|---|---|---|---|
| Force Hot Water | Forces immediate hot water heating regardless of schedule | check_circle | tune |
| COP | Efficiency ratio - heat output divided by electricity input | check_circle | remove |
| Thermostat Temp #1 | Desired room temperature set for heating zone #1 | check_circle | tune |
| Target Temp #1 | Target water temperature for the heating circuit in zone #1 | check_circle | remove |
| Defrost Mode | Indicates when the outdoor unit is melting ice buildup | check_circle | remove |
| Delta Temp | Difference between the water leaving and returning to the heat pump, used to show how much heat is being transferred | check_circle | remove |
| Prohibit Heating Hot Water | When enabled, prevents hot water heating | check_circle | tune |
| Tank Water Temp | Current temperature of the domestic hot water stored in the tank | check_circle | remove |
| Target Tank Water Temp | Desired domestic hot water tank temperature | check_circle | tune |
| Input Power | Estimated electrical power being consumed | check_circle | remove |
| Output Power | Estimated heat energy being produced | check_circle | remove |
| Error Code | Diagnostic code shown when there is a problem | check_circle | remove |
| Has Error | Indicates if the system has an active error | check_circle | remove |
| Flow Rate | Amount of water flowing through the system in litres per minute | check_circle | remove |
| Flow Rate | Amount of water flowing through the system in litres per minute | check_circle | remove |
| Operation Mode | Current mode: heating, cooling, or hot water production. May also show other modes like antifreeze or legionella. | check_circle | remove |
| Indoor Temp #1 | Current air temperature in rooms served by heating zone #1 | check_circle | remove |
| Thermostat Temp #1 | Desired room temperature set for heating zone #1 | check_circle | tune |
| Return Temp | Water temperature returning to the heat pump from the heating system | check_circle | remove |
| Operation Mode | Current mode: heating, cooling, or hot water production. May also show other modes like antifreeze or legionella. | check_circle | remove |
| Operation Mode | Current mode: heating, cooling, or hot water production. May also show other modes like antifreeze or legionella. | check_circle | remove |
| Outdoor Temp | Current outside air temperature measured near the heat pump | check_circle | remove |
| Flow Temp | Water temperature leaving the heat pump and going into the heating system | check_circle | remove |
| Flow Temp Boiler | Water temperature leaving the backup boiler | check_circle | remove |
| Target Temp #1 | Target water temperature for the heating circuit in zone #1 | check_circle | remove |
| Liquid Line Temp | Temperature of the liquid refrigerant flowing through the heat pump's cooling circuit | check_circle | remove |
| Power | Whether the heat pump is turned on or off | check_circle | tune |
| Water Pump 1 Status | Shows if the water circulation pump is running | check_circle | remove |
| Operation Mode #1 | Operating mode for heating zone #1. In most heat pumps this is either constant flow or compensation curve mode, but some models may support advanced modes like auto-adaptation. | check_circle | tune |
| Compressor Status | Shows whether the compressor is currently running or idle | check_circle | remove |
App-level features
Automation and optimization modes that MelPump unlocks for this integration.
bolt
Summer Eco mode
bolt
Smart Energy (dynamic pricing)
bolt
Solar Mode - Hot Water
bolt
Solar Mode - Zone Heating
bolt
Night mode
bolt
Advanced Scheduler
bolt
Push and Email Notifications
bolt
Energy Estimation